- 空气冷却、水冷却
- 3极管
- 4极管
- 用途:用于工业诱电加热以及诱导加热
|
 |
技术资料(送信管) |

打开新窗口 |
三极管(阳极损耗 不满1000W)
| Type |
Heater
or Filament |
Trans
Conduct.
(ms) |
Amp.
Factor
μ |
Max
Freq.
(MHz) |
Max.
Plate Ratings |
Output
Power
(kW) |
Cooling |
Volt
(V) |
Curr.
(A) |
Volt.
(kV) |
Curr.
(mA) |
Diss.
(W) |
| 6T58RA |
5 |
22 |
4.5 |
17 |
110 |
6 |
650 |
800 |
2.4 |
FA |
| E3061C** |
6.3 |
32 |
6.5 |
45 |
50 |
7.5 |
750 |
800 |
2.5 |
FA |
| 7815 * |
6 |
0.98 |
25 |
100 |
3,000 |
2 |
10 |
10 |
- |
C |
Notes
1.* 为量产品、**
为用于维修品种
2.FA : Forced Air Cooling C : Conduction Cooling
※单击有下划线的文字将打开新窗口
三极管(阳极损耗
1kW~10kW以下)
| Type |
Heater
or Filament |
Trans
Conduct.
(ms) |
Amp.
Factor
μ |
Max
Freq.
(MHz) |
Max.
Plate Ratings |
Output
Power
(kW) |
Cooling |
Volt
(V) |
Curr.
(A) |
Volt.
(kV) |
Curr.
(A) |
Diss.
(kW) |
| 7T69RB |
12.6 |
35 |
13 |
21 |
110 |
8 |
2 |
4.5 |
9 |
FA |
| 7T82JA |
5 |
22 |
4.5 |
17 |
110 |
6 |
0.65 |
1.5 |
2.4 |
W |
| 7T84B |
6.3 |
22 |
4.5 |
17 |
110 |
7 |
0.8 |
2 |
3.8 |
W |
| 7T84RB |
6.3 |
22 |
4.5 |
17 |
110 |
7 |
0.8 |
1.5 |
3.8 |
FA |
| 7T85RB |
6.3 |
35 |
5 |
21 |
110 |
8 |
1 |
2.5 |
5.1 |
FA |
| E3062E |
6.3 |
32 |
6.3 |
25 |
70 |
7.5 |
0.75 |
1.5 |
3.4 |
FA |
| 8T20B |
12 |
40 |
11 |
21 |
45 |
12 |
2.5 |
10 |
18 |
W |
| 8T20RB |
12 |
40 |
11 |
21 |
45 |
12 |
2.5 |
10 |
16 |
FA |
| 8T30A |
12 |
40 |
6.6 |
50 |
30 |
12 |
2 |
6 |
11 |
W |
| 8T30RA |
12 |
40 |
6.6 |
50 |
30 |
12 |
2 |
6 |
11 |
FA |
| 8T64B |
12 |
40 |
8 |
20 |
45 |
12 |
2 |
10 |
13 |
W |
| 8T64RB |
12 |
40 |
8 |
20 |
45 |
12 |
2 |
6 |
13 |
FA |
| 8T69JB |
12.6 |
35 |
12 |
21 |
110 |
8 |
2 |
6 |
9 |
W |
| 8T85RB |
12 |
40 |
11 |
21 |
40 |
12 |
2.5 |
10 |
17.5 |
FA |
| E3069 |
12.6 |
35 |
13 |
21 |
110 |
8 |
2.2 |
5 |
11 |
FA |
| E3097 ** |
6.3 |
22 |
6.5 |
35 |
- |
20 |
0.8 |
1.5 |
- |
FA |
| E3130 |
12.6 |
45 |
17 |
21 |
110 |
8 |
2.5 |
6 |
13 |
FA |
| E3170 |
12.6 |
35 |
10 |
21 |
110 |
8 |
2.2 |
5 |
11 |
FA |
Notes
1.* 为量产品、**
为用于维修品种
2.FA : Forced Air Cooling C : Conduction Cooling
※单击有下划线的文字将打开新窗口
三极管(阳极损耗
10kW~100kW以下)
| Type |
Heater
or Filament |
Trans
Conduct.
(ms) |
Amp.
Factor
μ |
Max
Freq.
(MHz) |
Max.
Plate Ratings |
Output
Power
(kW) |
Cooling |
Volt
(V) |
Curr.
(A) |
Volt.
(kV) |
Curr.
(A) |
Diss.
(kW) |
8T25RA
|
7.5~
8.5 |
110 |
24 |
20 |
40 |
14 |
4.5 |
15 |
31 |
FA |
| 8T25 |
20 |
31 |
W |
| 8T61A |
8 |
280 |
30 |
20 |
40 |
14 |
8.5 |
35 |
57 |
W |
| 8T72B |
8 |
180 |
16 |
20 |
40 |
14 |
6.5 |
25 |
40 |
W |
| 8T84A |
8 |
180 |
16 |
20 |
40 |
14 |
6.5 |
30 |
42 |
W |
| 8T85B |
12 |
40 |
11 |
21 |
45 |
12 |
3 |
13 |
22 |
W |
| 8T86B |
12 |
40 |
11 |
21 |
45 |
12 |
3 |
13 |
22 |
W |
| 8T87B |
8 |
180 |
16 |
20 |
40 |
14 |
5 |
30 |
42 |
W |
| 8T87RB |
8 |
180 |
16 |
20 |
40 |
14 |
5 |
20 |
35 |
FA |
| 9T16B ** |
8 |
280 |
30 |
20 |
40 |
12 |
8.5 |
50 |
57 |
V |
| 9T64B |
12 |
320 |
70 |
30 |
25 |
15 |
15 |
75 |
137 |
W |
| 9T71C |
11 |
285 |
38 |
30 |
25 |
17 |
13 |
75 |
130 |
W |
| 9T94A |
13 |
320 |
70 |
30 |
25 |
16 |
16 |
80 |
170 |
W |
| E3116 |
8 |
280 |
30 |
20 |
40 |
14 |
8.5 |
25 |
57 |
FA |
Notes
1.* 为量产品、**
为用于维修品种
2.FA : Forced Air Cooling C : Conduction Cooling
※单击有下划线的文字将打开新窗口
三极管(阳极损耗
100kW以上)
| Type |
Heater
or Filament |
Trans
Conduct.
(ms) |
Amp.
Factor
μ |
Max
Freq.
(MHz) |
Max.
Plate Ratings |
Output
Power
(kW) |
Cooling |
Volt
(V) |
Curr.
(A) |
Volt.
(kV) |
Curr.
(A) |
Diss.
(kW) |
9T38A/
LD961 |
18.3 |
315 |
90 |
40 |
2 |
15 |
20 |
120 |
210 |
W |
| 9T40 ** |
18 |
315 |
80 |
40 |
2 |
15 |
20 |
150 |
240 |
V |
| 9T82B * |
16.5 |
325 |
65 |
30 |
30 |
16 |
20 |
120 |
215 |
W |
| 9T83 ** |
18 |
315 |
80 |
40 |
2 |
15 |
20 |
150 |
240 |
V |
E3050/
9T75 |
17.5 |
470 |
130 |
30 |
2 |
15 |
40 |
250 |
450 |
W |
| E3085 |
15.8~
18 |
450 |
130 |
30 |
2 |
15 |
40 |
250 |
320 |
W |
| E3109 * |
18 |
315 |
80 |
40 |
2 |
15 |
20 |
150 |
240 |
V |
Notes
1.* 为量产品、**
为用于维修品种
2.FA : Forced Air Cooling C : Conduction Cooling
※单击有下划线的文字将打开新窗口 四极管<阳极损耗
1000W以下>
| Type |
Heater or Filament |
Trans
Conduct.
(ms) |
Use
|
Max
Freq.
(MHz) |
Max. Ratings |
Plate
Output
(W) |
Cooling |
Volt
(V) |
Curr.
(A) |
Plate
Volt.
(V) |
Plate
Curr.
(mA) |
Plate
Diss.
(W) |
| 7F37R |
4.0 |
35 |
15(0.4) |
CT *
ABI**
SSB |
130
30 |
4000
5000 |
700
700 |
1000
1000 |
1250
1800 |
FA |
Notes
1.*表示运行实例在90MHz的时候。**表示运行实例在30MHz以下的时候。
2.FA : Forced Air Cooling
※单击有下划线的文字将打开新窗口。
四极管<阳极损耗 10KW以下>
| Type |
Heater or Filament |
Trans
Conduct.
(ms) |
Use
|
Max
Freq.
(MHz) |
Max. Ratings |
Plate
Output
(W) |
Cooling |
Volt
(V) |
Curr.
(A) |
Plate
Volt.
(V) |
Plate
Curr.
(A) |
Plate
Diss.
(W) |
| 7F71R |
4.0 |
78 |
65 (1.6) |
CT *
BTV** |
130
300 |
5000
5000 |
1.8
1.8 |
3500
3500 |
5000
1100 |
FA |
| 8F45R |
7.5 |
75 |
23 (1.0) |
CT
CP
ABI |
110
110
110 |
8000
5500
8000 |
3.0
2.5
3.0 |
5000
5000
5000 |
14000
5500
6000 |
FA |
| E3030B |
7.5 |
24 |
8.3 (0.2) |
Switch & regulator |
- |
100000 |
***5 |
1500 |
- |
OFA |
| E3113 |
7.5 |
17 |
8.2 (0.2) |
Switch |
- |
150000 |
***3 |
1300 |
- |
O |
Notes
1.*表示运行实例在90MHz的时候。**表示运行实例在30MHz以下的时候。***表示脉冲峰值。
2.FA : Forced Air Cooling OFA : Oil or Forced air cooling O : Oil cooling
※单击有下划线的文字将打开新窗口。
四极管<阳极损耗
10KW以上>
| Type |
Heater or Filament |
Trans
Conduct.
(ms) |
Use
|
Max
Freq.
(MHz) |
Max. Ratings |
Plate
Output
(kW) |
Cooling |
Volt
(V) |
Curr.
(A) |
Plate
Volt.
(V) |
Plate
Curr.
(A) |
Plate
Diss.
(kW) |
| 8F67R |
6.9-7.5 |
126 |
65 (3.0) |
CT
BTV**
|
230
230 |
8000
8000 |
4.5
6 |
15
15 |
15.5***
15.2*** |
FA |
| 8F68 |
8.5 |
185 |
85 (3.0) |
CT
BTV* |
220
220 |
11000
11000 |
9
12
|
30
30 |
40
30 |
VF |
| 8F68R |
8.5 |
185 |
85 (3.0) |
CT
BTV* |
220
220 |
10000
10000 |
8
10 |
25
25 |
40
30 |
FA |
| 8F76R |
7.5 |
120 |
60 (2.5) |
CT
BTV* |
250
250 |
10000
10000 |
4.5
5.5 |
15
15 |
15
12 |
FA |
| 9F45 |
16 |
345 |
150 (10) |
CT**
CP** |
30
30 |
15000
15000 |
25
20 |
150
100 |
250
150 |
VF |
Notes
1.*表示运行实例在6.0MHz的时候,接近同步信号时的值。
*表示运行实例为电极接地。**表示运行实例在30MHz以下的时候。***有效输出
2.FA : Forced Air Cooling VF : Vapor cooling, Forced ventilation
|